Review



1d pulse sequence  (Bruker Corporation)


Bioz Verified Symbol Bruker Corporation is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 97

    Structured Review

    Bruker Corporation 1d pulse sequence
    1d Pulse Sequence, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 3085 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+pulse+sequence/Diffusion/pmc12992617-217-23-37
    Average 97 stars, based on 3085 article reviews
    1d pulse sequence - by Bioz Stars, 2026-10
    97/100 stars

    Images

    Related Articles

    Sequencing:

    Article Title: Cooperative anion activation at a cobalt center through ion pairing and ligand design
    Article Snippet: .. Before recording the DOSY experiment, the values of δ (small delta) and Δ (big delta) were optimized for each complex by using the 1D pulse sequence for diffusion measurements (ledbpgp2s1d, δ (2 × P30) and Δ (d20), Bruker’s software). ..

    Article Title: Metabolomic and lipoproteomic differences and similarities between COVID-19 and other types of pneumonia.
    Article Snippet: .. Pulse sequence (Bruker library) N. of scans Data points Spectral width (Hz) Aquisition time (s) Relaxation delay (s) NOESY noesygppr1d.comp 32 96 k 18,028 2.7 4 CPMG cpmgpr1d.comp 32 72 k 12,019 3.07 4 Diffusion-edited ledbgppr2s1d.comp 32 96 k 18,028 2.7 4 Table 2. ..

    Article Title: Kinetics and Mechanism of Azole n-π* Catalyzed Amine Acylation
    Article Snippet: .. 1H spectra obtained in 16 increments along the diffusion dimension, with quadratic (q) ramping between 5 % (fz = 0.05) and 95 % (fz = 0.95) of the maximum gradient strength of the probe, using Bruker’s ledbpgp2s pulse sequence, a diffusion delay of Δ = 75 ms, bipolar pulse duration of δ/2 = 550 μs, Eddy current delay of 5 ms, gradient recovery delay of 0.20 ms, and sine bell-shaped shaped gradient pulses. ..

    Article Title: Green and efficient cell wall nano-reconstruction under ambient temperature towards strong cellulosic aerogels
    Article Snippet: Solute aliquots were collected during NaOD treatment from 30 min to 24 h. Measurements were made using a Bruker Avance III HD 400 MHz. .. The diffusion-edited 1H experiment used a 1D diffusion-ordered spectroscopy (DOSY) pulse sequence based on stimulated echo and bipolar gradient pulses (Bruker pulse program ‘ledbpgp2s1d’), with 3 s relaxation delay (d1), 0.5 s acquisition time (aq), 16 dummy scans (ds), 512 transient scans (ns), a sweep-width (sw) of 20 ppm with the transmitter offset on 6.1 ppm (o1p), diffusion time (d20) of 200 ms, gradient recovery delay (d16) of 0.2 ms, eddy current delay (d21) of 5 ms, diffusion gradient pulse duration (p30) of 2.5 ms, and z-gradient strength (gpz6) of 80% at >50 G cm−1 (probe z-gradient strength). .. Acquisitions were performed at 338 K. Data were processed with MestreNova (Mestrelab Research) software using a 90° shifted square sine-bell apodization window, baseline and phase correction were applied.

    Article Title: Nonuniform Chiralization of Metal–Organic Frameworks Using Imine Chemistry
    Article Snippet: Standard Bruker parameters set were used for magnitude mode COSY (cosygpppqf), edited HSQC (hsqcedetgpissp2.3), and HMBC (hmbcgplpndqf). .. The Bruker DOSY pulse sequence (ledbpgp2s) was used to measure diffusion coefficients. ..

    Article Title: Revealing Organophosphorus and Carbamate Interactions with Albumin Using 1 H NOE Pumping NMR Technique.
    Article Snippet: .. 1H NOE pumping experiments were measured with a slightly modified pulse sequence originally developed and described by Chen and Shapiro.21 The standard Bruker diffusion pulse sequence BPPLED (Bipolar Pulse Pair Longitudinal Eddy current Delay, ledbpgp2s1d)25 was modified to include a CPMG-based26,27 T2-filter prior to the acquisition period to remove the unwanted protein signals. ..

    Article Title: Revealing Organophosphorus and Carbamate Interactions with Albumin Using 1 H NOE Pumping NMR Technique
    Article Snippet: .. The standard Bruker diffusion pulse sequence BPPLED (Bipolar Pulse Pair Longitudinal Eddy current Delay, ledbpgp2s1d) was modified to include a CPMG-based , T 2 -filter prior to the acquisition period to remove the unwanted protein signals. ..

    Article Title: On the determination of charge and nitrogen content in cellulose fibres modified to contain quaternary amine functionality.
    Article Snippet: Measurements were performed at 65 ◦C using a Bruker Avance III HD 400 MHz. .. Diffusion-edited 1H measurements were acquired using a 1D bipolar-pulse pair with stimulated echo-diffusion-ordered spectroscopy pulse sequence (‘ledbpgp2s1d’ Bruker pulse program) with the following parameters: 3 s relaxation time, 0.5 s acquisition time, 16 dummy scans and 512 transient scans. ..

    Diffusion-based Assay:

    Article Title: Cooperative anion activation at a cobalt center through ion pairing and ligand design
    Article Snippet: .. Before recording the DOSY experiment, the values of δ (small delta) and Δ (big delta) were optimized for each complex by using the 1D pulse sequence for diffusion measurements (ledbpgp2s1d, δ (2 × P30) and Δ (d20), Bruker’s software). ..

    Article Title: Metabolomic and lipoproteomic differences and similarities between COVID-19 and other types of pneumonia.
    Article Snippet: .. Pulse sequence (Bruker library) N. of scans Data points Spectral width (Hz) Aquisition time (s) Relaxation delay (s) NOESY noesygppr1d.comp 32 96 k 18,028 2.7 4 CPMG cpmgpr1d.comp 32 72 k 12,019 3.07 4 Diffusion-edited ledbgppr2s1d.comp 32 96 k 18,028 2.7 4 Table 2. ..

    Article Title: Kinetics and Mechanism of Azole n-π* Catalyzed Amine Acylation
    Article Snippet: .. 1H spectra obtained in 16 increments along the diffusion dimension, with quadratic (q) ramping between 5 % (fz = 0.05) and 95 % (fz = 0.95) of the maximum gradient strength of the probe, using Bruker’s ledbpgp2s pulse sequence, a diffusion delay of Δ = 75 ms, bipolar pulse duration of δ/2 = 550 μs, Eddy current delay of 5 ms, gradient recovery delay of 0.20 ms, and sine bell-shaped shaped gradient pulses. ..

    Article Title: Green and efficient cell wall nano-reconstruction under ambient temperature towards strong cellulosic aerogels
    Article Snippet: Solute aliquots were collected during NaOD treatment from 30 min to 24 h. Measurements were made using a Bruker Avance III HD 400 MHz. .. The diffusion-edited 1H experiment used a 1D diffusion-ordered spectroscopy (DOSY) pulse sequence based on stimulated echo and bipolar gradient pulses (Bruker pulse program ‘ledbpgp2s1d’), with 3 s relaxation delay (d1), 0.5 s acquisition time (aq), 16 dummy scans (ds), 512 transient scans (ns), a sweep-width (sw) of 20 ppm with the transmitter offset on 6.1 ppm (o1p), diffusion time (d20) of 200 ms, gradient recovery delay (d16) of 0.2 ms, eddy current delay (d21) of 5 ms, diffusion gradient pulse duration (p30) of 2.5 ms, and z-gradient strength (gpz6) of 80% at >50 G cm−1 (probe z-gradient strength). .. Acquisitions were performed at 338 K. Data were processed with MestreNova (Mestrelab Research) software using a 90° shifted square sine-bell apodization window, baseline and phase correction were applied.

    Article Title: Nonuniform Chiralization of Metal–Organic Frameworks Using Imine Chemistry
    Article Snippet: Standard Bruker parameters set were used for magnitude mode COSY (cosygpppqf), edited HSQC (hsqcedetgpissp2.3), and HMBC (hmbcgplpndqf). .. The Bruker DOSY pulse sequence (ledbpgp2s) was used to measure diffusion coefficients. ..

    Article Title: Revealing Organophosphorus and Carbamate Interactions with Albumin Using 1 H NOE Pumping NMR Technique.
    Article Snippet: .. 1H NOE pumping experiments were measured with a slightly modified pulse sequence originally developed and described by Chen and Shapiro.21 The standard Bruker diffusion pulse sequence BPPLED (Bipolar Pulse Pair Longitudinal Eddy current Delay, ledbpgp2s1d)25 was modified to include a CPMG-based26,27 T2-filter prior to the acquisition period to remove the unwanted protein signals. ..

    Article Title: Revealing Organophosphorus and Carbamate Interactions with Albumin Using 1 H NOE Pumping NMR Technique
    Article Snippet: .. The standard Bruker diffusion pulse sequence BPPLED (Bipolar Pulse Pair Longitudinal Eddy current Delay, ledbpgp2s1d) was modified to include a CPMG-based , T 2 -filter prior to the acquisition period to remove the unwanted protein signals. ..

    Article Title: On the determination of charge and nitrogen content in cellulose fibres modified to contain quaternary amine functionality.
    Article Snippet: Measurements were performed at 65 ◦C using a Bruker Avance III HD 400 MHz. .. Diffusion-edited 1H measurements were acquired using a 1D bipolar-pulse pair with stimulated echo-diffusion-ordered spectroscopy pulse sequence (‘ledbpgp2s1d’ Bruker pulse program) with the following parameters: 3 s relaxation time, 0.5 s acquisition time, 16 dummy scans and 512 transient scans. ..

    Spectroscopy:

    Article Title: Green and efficient cell wall nano-reconstruction under ambient temperature towards strong cellulosic aerogels
    Article Snippet: Solute aliquots were collected during NaOD treatment from 30 min to 24 h. Measurements were made using a Bruker Avance III HD 400 MHz. .. The diffusion-edited 1H experiment used a 1D diffusion-ordered spectroscopy (DOSY) pulse sequence based on stimulated echo and bipolar gradient pulses (Bruker pulse program ‘ledbpgp2s1d’), with 3 s relaxation delay (d1), 0.5 s acquisition time (aq), 16 dummy scans (ds), 512 transient scans (ns), a sweep-width (sw) of 20 ppm with the transmitter offset on 6.1 ppm (o1p), diffusion time (d20) of 200 ms, gradient recovery delay (d16) of 0.2 ms, eddy current delay (d21) of 5 ms, diffusion gradient pulse duration (p30) of 2.5 ms, and z-gradient strength (gpz6) of 80% at >50 G cm−1 (probe z-gradient strength). .. Acquisitions were performed at 338 K. Data were processed with MestreNova (Mestrelab Research) software using a 90° shifted square sine-bell apodization window, baseline and phase correction were applied.

    Article Title: On the determination of charge and nitrogen content in cellulose fibres modified to contain quaternary amine functionality.
    Article Snippet: Measurements were performed at 65 ◦C using a Bruker Avance III HD 400 MHz. .. Diffusion-edited 1H measurements were acquired using a 1D bipolar-pulse pair with stimulated echo-diffusion-ordered spectroscopy pulse sequence (‘ledbpgp2s1d’ Bruker pulse program) with the following parameters: 3 s relaxation time, 0.5 s acquisition time, 16 dummy scans and 512 transient scans. ..

    Modification:

    Article Title: Revealing Organophosphorus and Carbamate Interactions with Albumin Using 1 H NOE Pumping NMR Technique.
    Article Snippet: .. 1H NOE pumping experiments were measured with a slightly modified pulse sequence originally developed and described by Chen and Shapiro.21 The standard Bruker diffusion pulse sequence BPPLED (Bipolar Pulse Pair Longitudinal Eddy current Delay, ledbpgp2s1d)25 was modified to include a CPMG-based26,27 T2-filter prior to the acquisition period to remove the unwanted protein signals. ..

    Article Title: Revealing Organophosphorus and Carbamate Interactions with Albumin Using 1 H NOE Pumping NMR Technique
    Article Snippet: .. The standard Bruker diffusion pulse sequence BPPLED (Bipolar Pulse Pair Longitudinal Eddy current Delay, ledbpgp2s1d) was modified to include a CPMG-based , T 2 -filter prior to the acquisition period to remove the unwanted protein signals. ..



    Similar Products

    97
    Bruker Corporation 1d pulse sequence
    1d Pulse Sequence, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+pulse+sequence/Diffusion/pmc12992617-217-23-37
    Average 97 stars, based on 1 article reviews
    1d pulse sequence - by Bioz Stars, 2026-10
    97/100 stars
      Buy from Supplier

    97
    Bruker Corporation diffusion pulse sequence bppled
    Diffusion Pulse Sequence Bppled, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+pulse+sequence/Diffusion/pm41605548-72-23-22
    Average 97 stars, based on 1 article reviews
    diffusion pulse sequence bppled - by Bioz Stars, 2026-10
    97/100 stars
      Buy from Supplier

    97
    Bruker Corporation 1d diffusion ordered spectroscopy dosy pulse sequence
    1d Diffusion Ordered Spectroscopy Dosy Pulse Sequence, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+pulse+sequence/Diffusion/10__1039_slash_d5gc03785a-263-6-20
    Average 97 stars, based on 1 article reviews
    1d diffusion ordered spectroscopy dosy pulse sequence - by Bioz Stars, 2026-10
    97/100 stars
      Buy from Supplier

    97
    Bruker Corporation ledbpgp2s pulse sequence
    Ledbpgp2s Pulse Sequence, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+pulse+sequence/Diffusion/pmc10436283__ja3c06258_si_001-870-36-35
    Average 97 stars, based on 1 article reviews
    ledbpgp2s pulse sequence - by Bioz Stars, 2026-10
    97/100 stars
      Buy from Supplier

    97
    Bruker Corporation pulse sequence
    Pulse Sequence, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+pulse+sequence/Diffusion/pm40032933-136-0-2
    Average 97 stars, based on 1 article reviews
    pulse sequence - by Bioz Stars, 2026-10
    97/100 stars
      Buy from Supplier

    97
    Bruker Corporation pulsed field gradient nmr sequences
    Pulsed Field Gradient Nmr Sequences, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+pulse+sequence/10__1016_slash_j__foodhyd__2024__110808-49-10-24
    Average 97 stars, based on 1 article reviews
    pulsed field gradient nmr sequences - by Bioz Stars, 2026-10
    97/100 stars
      Buy from Supplier

    97
    Bruker Corporation bruker dosy pulse sequence
    Bruker Dosy Pulse Sequence, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+pulse+sequence/Diffusion/pmc12082358__mg4c00139_si_001-83-1-1
    Average 97 stars, based on 1 article reviews
    bruker dosy pulse sequence - by Bioz Stars, 2026-10
    97/100 stars
      Buy from Supplier

    97
    Bruker Corporation echo diffusion ordered spectroscopy pulse sequence
    Echo Diffusion Ordered Spectroscopy Pulse Sequence, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+pulse+sequence/Diffusion/pm39486964-118-12-17
    Average 97 stars, based on 1 article reviews
    echo diffusion ordered spectroscopy pulse sequence - by Bioz Stars, 2026-10
    97/100 stars
      Buy from Supplier

    90
    Bruker Corporation 1d bipolar-pulse pair with stimulated echo-diffusion-ordered spectroscopy pulse sequence (ledbpgp2s1d)
    1d Bipolar Pulse Pair With Stimulated Echo Diffusion Ordered Spectroscopy Pulse Sequence (Ledbpgp2s1d), supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+pulse+sequence/pulse+program+ledbpgp2s/pm39486964-118-7-17
    Average 90 stars, based on 1 article reviews
    1d bipolar-pulse pair with stimulated echo-diffusion-ordered spectroscopy pulse sequence (ledbpgp2s1d) - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    Image Search Results